Amps to Kilowatts Calculator
This calculator converts a current in amps into power in kilowatts, using your voltage and power factor.
Change any number below — your result updates instantly, no button to click.
Your details
Results
Measure or improve the real-world result
These tools are relevant to the numbers above; you do not need them to use the calculator.
As an Amazon Associate we earn from qualifying purchases. We may earn a commission from links on this page, at no extra cost to you.
How it works
DC or single-phase kilowatts = amps × volts × power factor ÷ 1,000. Balanced three-phase kilowatts = √3 × line current × line-to-line volts × power factor ÷ 1,000.
Amps to kilowatts chart
The first two columns are DC or single-phase at power factor 1. The last column is balanced three-phase at 400 V line-to-line and power factor 0.8.
| Current | 120 V, 1-phase | 230 V, 1-phase | 400 V, 3-phase, PF 0.8 |
|---|---|---|---|
| 5 A | 0.60 kW | 1.15 kW | 2.77 kW |
| 10 A | 1.20 kW | 2.30 kW | 5.54 kW |
| 15 A | 1.80 kW | 3.45 kW | 8.31 kW |
| 20 A | 2.40 kW | 4.60 kW | 11.09 kW |
| 30 A | 3.60 kW | 6.90 kW | 16.63 kW |
| 40 A | 4.80 kW | 9.20 kW | 22.17 kW |
| 50 A | 6.00 kW | 11.50 kW | 27.71 kW |
Do not infer available circuit capacity from these arithmetic results. Use equipment and circuit ratings with applicable electrical requirements.
Worked example: 20 A at 230 V and 0.8 power factor
Multiply 20 A × 230 V × 0.8, then divide by 1,000. The result is 3.68 kW of real power.
At power factor 1, the same voltage and current would equal 4.6 kW. Power factor therefore changes the real kilowatts even when the volt and amp readings stay the same.
Amps alone cannot determine kilowatts
Current must be paired with voltage. Ten amps at 12 V DC is 0.12 kW, while 10 A at 230 V single-phase is 2.3 kW at power factor 1. For AC, real power also depends on power factor and the selected system.
For a balanced three-phase load at 400 V line-to-line and power factor 0.8, 10 A is about 5.54 kW. Unbalanced systems need phase-by-phase measurements rather than this balanced-load shortcut.
Kilowatts are power, not energy or electricity cost
The result describes a rate at one operating condition. To estimate energy, multiply kW by hours: a 3.68 kW load held for 2 hours uses 7.36 kWh. Multiply that energy by your electricity rate to estimate cost.
Motors, compressors, chargers, and variable-speed equipment may not hold one current or power factor throughout a cycle. Use representative measured values when estimating energy, and use nameplate/manufacturer requirements for electrical sizing.
Sources used for assumptions: Schneider Electric — single-phase and balanced three-phase power calculations; U.S. Energy Information Administration — electricity glossary; Klein Tools — CL390 true-RMS clamp meter specifications.
Frequently asked questions
How many kW is 20 amps?
At 230 V and power factor 1, that is 4.6 kW. At 120 V it is 2.4 kW. Voltage matters, so enter yours.
When is power factor not 1?
For inductive loads like motors and compressors, often around 0.8. DC and resistive heating are 1.
Why convert amps to kW?
To compare a measured operating current with real-power ratings and to estimate energy after adding operating time. Use manufacturer data and qualified guidance—not this conversion alone—for electrical sizing.
How many kW is 10 amps at 230 V?
At power factor 1, 10 A at 230 V is 2.3 kW. At power factor 0.8, it is 1.84 kW.
Does this calculate three-phase power?
Yes, for a balanced three-phase load. Select three-phase and enter line current, line-to-line voltage, and power factor. Unbalanced systems require phase-by-phase calculation or measurement.
Related calculators
Kilowatts to Amps Calculator
This calculator converts power in kilowatts into the current it draws in amps, using your …
ConversionsAmps to Watts Calculator
This calculator converts a current in amps into power in watts, using your voltage and pow…
ConversionskW to kWh Calculator
Power (kW) is the rate of use; energy (kWh) is power used over time. This calculator conve…